Skip to main content
Search Interpretations

Interpretation ID: aiam0147

Mr. Eugene D. Prahst, Chief Product Engineer, Dump Trailer Division, The Heil Company, 3000 W. Montana Street, Milwaukee, WI 53201; Mr. Eugene D. Prahst
Chief Product Engineer
Dump Trailer Division
The Heil Company
3000 W. Montana Street
Milwaukee
WI 53201;

Dear Mr. Prahst: Thank you for your letter of February 24, 1969, to the Office o Standards Preparation, concerning the proposed lighting equipment on your dump trailers.; The lamps and reflectors shown on your drawing 701B1907 dated Februar 20, 1969, appear to be in conformance with the requirements of Standard No. 108 with the following exceptions:; >>>1. The required license plate lamp is not shown. 2. The minimum mounting height for reflectors is 15 inches. 3. With respect to maximum mounting zones for lamps and reflectors, th limiting dimensions of 16, 30, and 24 inches indicated on your drawing appear to be too liberal for a trailer with essentially square corners.; 4. With reference to Notes 2 and 3 on your drawing, certai restrictions as specified in paragraph S3.3 of Standard No. 108 are applicable for combination lamps.<<<; With respect to the requirements of Standard No. 108, I must point ou that this Bureau does not issue approvals on items of lighting equipment or on vehicle designs incorporating this equipment. Therefore, the above comments are for your information only, and in no way relieve the vehicle manufacturer from his responsibility for certifying that the assembled vehicle meets the requirements of Standard No. 108.; Sincerely, Charles A. Baker, Office of Standards on Accident Avoidance Motor Vehicle Safety Performance Service;