Skip to main content
Search Interpretations

Interpretation ID: 9544

Mr. Bob Carver
Product Engineering
Wayne Wheeled Vehicles
13311 Industrial Parkway
Marysville, OH 43040

Dear Mr. Carver:

This responds to your letter of January 8, 1994, asking two questions concerning a recent amendment to Standard No. 217, Bus Emergency Exits and Window Retention and Release (57 FR 49413; November 2, 1992). Your questions and the response to each follow.

1.There's some confusion here in our engineering department regarding the interpretation of the "Daylight Opening" and "Unobstructed Opening" as it applies to the new side emergency door specification in FMVSS 217. Page 2 shows the allowable obstruction and the context in which "Daylight Opening" and "Unobstructed Opening" are used. Page 3 shows some measurements of our seats placed according to the "30 cm minimum" shown on page 2. Page 4 shows four different interpretations of the "Unobstructed Opening" area. Depending on the interpretation, between 9 and 15 people may be accommodated by a side emergency door. My question is this: of the four possibilities shown, which definition of the "Unobstructed Opening" area is correct? Mr. Hott indicated definition 4.

The term "daylight opening" is defined in the Final Rule as "the maximum unobstructed opening of an emergency exit when viewed from a direction perpendicular to the plane of the opening." An obstruction in this context would include any obstacle or object that would block, obscure, or interfere with, in any way, access to that exit when opened. In determining the "maximum unobstructed opening of an emergency exit," we would subtract, from the total area of the opening, the area of any portions of the opening that cannot be used for exit purposes as a result of the obstruction. The area measurements would be taken when viewed from a direction perpendicular to the plane of the opening.

Your question specifically concerns how the "maximum unobstructed opening" of a side door is measured when the opening is partially obstructed by a seat. In the case of the illustrated door exit, occupants would use the exit by movement along the floor. This would be considered in determining the extent of an obstruction. None of the four examples you enclosed with your letter correctly illustrates the area that would be credited for the illustrated exit. The following regions would not be credited for this exit: (1) the area visually obstructed by the seat; (2) your region A2, an area bounded by a horizontal line tangent to the top of the seat back, a vertical line tangent to the rearmost portion of the top of the seat, the upper edge of the door opening, and the edge of the door forward of the seat; (3) your region A5, an area bounded by the seat back, a horizontal line tangent to the top of the seat back, and the edge of the door forward of the seat; and (4) your region A8, an area bounded by the seat leg, the floor, the lower edge of the seat bottom, and the edge of the door forward of the seat. Because the seat would make the last three regions unusable as exit space for a person traveling along the floor of the bus towards the exit, they would not be credited for that exit.

You should be aware that the agency published a notice of proposed rulemaking to amend Standard No. 217 on December 1, 1993 (58 FR 63321). The notice proposed two alternate means for determining the maximum amount of area that will be credited for all types of emergency exits on school buses. The agency is currently reviewing the comments received in response to this notice. I am enclosing a copy of this notice.

2.Here is an excerpt from FMVSS 217 S5.5.3(a):

"Each school bus ....shall have the designation "Emergency Door" or "Emergency Exit" as appropriate, .... For emergency exit doors, the designation shall be located at the top of, or directly above, the emergency exit door on both the inside and outside surfaces of the bus..... For emergency window exits, the designation shall be located at the top of, or directly above, or at the bottom of the emergency window exit on both the inside and outside surfaces of the bus."

I've seen a two-sided sticker used by other bus manufacturers. It is applied on the inside surface of a window and the same image "Emergency Door" or "Emergency Exit" can be read from both inside and outside the bus. Is it permissible for us to use this sort of decal, assuming it meets all other (i.e., FMVSS 302)?

The answer to your question is yes. The agency addressed this issue in an October 2, 1978, letter to Mr. E.M. Ryan of Ward Industries, Inc. I am enclosing a copy of this letter.

I hope you find this information helpful. If you have any other questions, please contact Walter Myers of my staff at this address or by phone at (202) 366-2992.

Sincerely,

John Womack Acting Chief Counsel

Enclosures

ref:217 d:3/24/94