Pasar al contenido principal
Search Interpretations

Interpretation ID: aiam1493

Mr. G. Meier, Technical Service Manager, Porsche/Audi, 818 Sylvan Avenue, Englewood Cliffs, NJ 07632; Mr. G. Meier
Technical Service Manager
Porsche/Audi
818 Sylvan Avenue
Englewood Cliffs
NJ 07632;

Dear Mr. Meier: This is in reference to your defect notification campaign (NHTSA No 73-0229) concerning possible fires resulting from a short in the radiator cooling fan in some Audi 100's.; The letter which you have sent to the owners of the involved vehicle does not entirely meet the requirements of 49 CFR Part 577. Specifically, the phrase, 'possible hazard that may exist in your vehicle,' may be construed as a disclaimer since it tends to discourage vehicle owners from having their vehicles corrected and is therefore not permitted. It is, however, permissible to state that the defect may not be present in every vehicle being campaigned if such a statement is applicable.; It will not be necessary to send an additional letter in this instance but all future defect notifications must comply with the applicable regulation. If you desire further information, please contact Messrs. W. J. Reinhart or James Murray at this office (202) 426-2840.; Sincerely, Andrew G. Detrick, Acting Director, Office of Defect Investigation, Motor Vehicle Programs;