Interpretation ID: nht87-2.16
TYPE: INTERPRETATION-NHTSA
DATE: JUNE 18, 1987
FROM: MARY F. BARRAS -- SALES ASSISTANT, CONTRACT ADMINISTRATION, M.A.N. TRUCK & BUS
TO: MICHAEL W. VORIS -- BUS PROCUREMENT SUPERVISOR, METRO
TITLE: CONTRACT NO. T/F 19-84 REAR EMERGENCY WINDOW
ATTACHMT: MEMO DATED 2-23-88, TO JAY COSTA, FROM ERIKA Z. JONES, STD 271, REDBOOK A31; MEMO DATED 7-1-87, TO ERIKA Z. JONES, FROM JAY COSTA; MEMO DATED 6-25-87, CONTRACT NO. T/F 19-83 REAR EMERGENCY WINDOW
TEXT: In response to your letter of June 16, 1987 I am providing the following information in regard to converting the rear emergency window to a non-openable type window.
According to FMVSS 217, a total of 4,355 square inches is required for this bus. Please see the attached FMVSS information provided in regard to the computations used to arrive at this figure. Our bus has 19 windows, including the rear window, which totals 536 square inches per window. The bus also has 3 roof hatches which total 506.25 square inches per hatch. Therefore, the computations are listed below: 536 sq. ins. x 19 windows, including rear = 10,184 sq. ins. 506.25 sq. ins. x 3 roof hatches = 1,519 sq. ins. *11,703 sq. ins. * This total can be considered the accountable square inches on the bus in regard to safety requirements set forth by FMVSS 217. Also, 1,742 square inches (40%) of one side of the bus is unobstructed thereby, complying with this standard.
Therefore, the rear emergency window may be changed and the bus will remain within the FMVSS 217 boundries.
May we suggest that Metro directly contact the window manufacturer in regard to any modification to be made to this window so that warranty provisions do not become void. Please feel free to contact Mr. Mike Hurtekant at Excel Industries at (219) 264 -2131 in Elkhart, Indiana. ATTACHMENTS